Remove the tower.のメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

Remove the tower. - メーカー・企業と製品の一覧

Remove the tower.の製品一覧

1~2 件を表示 / 全 2 件

表示件数

[Delivery Example] Ethylene Oxide and Propylene Oxide Removal Tower

Remove to below 40ppm from 715,000ppm! React and convert EG and PG with dilute sulfuric acid solution.

We would like to introduce a case study of the ethylene oxide and propylene oxide removal tower delivered by E-Techno. The gas temperature is 60°C, and the convergence temperature due to reaction heat is 72.1°C. The reaction converts EG and PG using a dilute sulfuric acid aqueous solution. The processing gas volume is 914.2 Nm³/h, and the design removal rate reduces the concentration from 715,000 ppm to below 40 ppm. 【Case Study】 ■ Industry of Delivery: Resin ■ Designed and Installed Equipment: Ethylene Oxide and Propylene Oxide Removal Tower ■ Processing Gas Volume: 914.2 Nm³/h ■ Target Substances for Removal: EO, PO ■ Gas Temperature: 60°C ■ Convergence Temperature Due to Reaction Heat: 72.1°C ■ Design Removal Rate: Reducing from 715,000 ppm to below 40 ppm *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Other environmental equipment
  • Gas recovery/treatment equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Case Study of Environmental Equipment Installation] Isopropyl Alcohol Removal Tower

Gas concentration is 9300 ppm! Case study of an isopropyl alcohol removal tower with a design removal rate of 80-90%.

We would like to introduce a case study of the isopropyl alcohol removal tower delivered by E-Techno. The target substance for removal is IPA, with a processing gas flow rate of 20m³/min, a supply water temperature of Max. 28°C, and a processing gas concentration of 9300 ppm. The absorbent liquid is water, and the designed removal rate is 80-90%. 【Case Study】 ■ Industry of the recipient: Chemical ■ Designed and installed equipment: Isopropyl Alcohol Removal Tower EHCU Series ■ Processing gas flow rate: 20m³/min ■ Target substance for removal: IPA ■ Gas temperature: Max. 35°C ■ Supply water temperature: Max. 28°C ■ Processing gas concentration: 9300 ppm ■ Designed removal rate: 80-90% *For more details, please refer to the PDF document or feel free to contact us.

  • others
  • Other environmental equipment
  • Gas recovery/treatment equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Remove the tower.の関連カテゴリ